Consistency of pacing and metabolic responses during 2000-m rowing ergometry

Gee, Thomas I., French, Duncan N., Gibbon, Karl C. and Thompson, Kevin G. (2013) Consistency of pacing and metabolic responses during 2000-m rowing ergometry. International Journal of Sports Physiology and Performance, 8 (1). pp. 70-76. ISSN 1555-0265

Full content URL: http://journals.humankinetics.com/ijspp-back-issue...

Documents
Consistency of pacing and metabolic responses during 2000-m rowing ergometry
[img]
[Download]
85040014.pdf
[img]
Preview
PDF
10Gee_IJSPP_2012-0092_70-76_ej.pdf - Whole Document

297kB
[img] PDF
85040014.pdf - Whole Document
Restricted to Repository staff only

7MB
Item Type:Article
Item Status:Live Archive

Abstract

PURPOSE: This study investigated the pacing strategy adopted and the consistency of performance and related physiological parameters across three 2000-m rowing-ergometer tests.

METHODS: Fourteen male well-trained rowers took part in the study. Each participant performed three 2000-m rowing-ergometer tests interspersed by 3-7 d. Throughout the trials, respiratory exchange and heart rate were recorded and power output and stroke rate were analyzed over each 500 m of the test. At the completion of the trial, assessments of blood lactate and rating of perceived exertion were measured.

RESULTS: Ergometer performance was unchanged across the 3 trials; however, pacing strategy changed from trial 1, which featured a higher starting power output and more progressive decrease in power, to trials 2 and 3, which were characterized by a more conservative start and an end spurt with increased power output during the final 500 m. Mean typical error (TE; %) across the three 2000-m trials was 2.4%, and variability was low to moderate for all assessed physiological variables (TE range = 1.4-5.1%) with the exception of peak lactate (TE = 11.5%).

CONCLUSIONS: Performance and physiological responses during 2000-m rowing ergometry were found to be consistent over 3 trials. The variations observed in pacing strategy between trial 1 and trials 2 and 3 suggest that a habituation trial is required before an intervention study and that participants move from a positive to a reverse-J-shaped strategy, which may partly explain conflicting reports in the pacing strategy exhibited during 2000-m rowing-ergometer trials.

Keywords:rowers, reliability, pacing strategy, cardiorespiratory, time trial
Subjects:C Biological Sciences > C600 Sports Science
Divisions:College of Social Science > School of Sport and Exercise Science