Characteristics of horizontal gas-liquid two-phase flow measurement in a medium-sized pipe using gamma densitometry

Baba, Yahaya D., Ribeiro, Joseph X.F., Aliyu, Aliyu , Archibong-Eso, Archibong, Abubakar, Umar D. and Ehinmowo, Adegboyega B. (2020) Characteristics of horizontal gas-liquid two-phase flow measurement in a medium-sized pipe using gamma densitometry. Scientific African, 10 . e00550. ISSN 2468-2276

Full content URL: https://doi.org/10.1016/j.sciaf.2020.e00550

Documents
Characteristics of horizontal gas-liquid two-phase flow measurement in a medium-sized pipe using gamma densitometry
Published Open Access Manuscript
[img]
[Download]
[img]
Preview
PDF
Baba et al - 2020 - Scientific African-10-e000550.pdf - Whole Document
Available under License Creative Commons Attribution 4.0 International.

1MB
Item Type:Article
Item Status:Live Archive

Abstract

Two-phase flows are common occurrences in many industrial applications. The understanding of their characteristics in industrial piping systems is vital for the efficient design, optimization, and operation of industrial processes. Most of the previous experimental studies involving the use of gamma densitometers for holdup measurements in air-water mixtures are limited to smaller diameter pipes (generally regarded as those with < 50 mm in nominal diameter). Further, very few literature report experimental data obtained using gamma desitometers. This paper presents an application of a gamma densitometer in the measurement of two-phase flow characteristics in an intermediate diameter pipe (nominal diameter between 50 mm and 100 mm). Scaled air-water experiments were performed in a 17-m long, 0.0764-m internal diameter horizontal pipe. Liquid superficial velocity ranged between 0.1–0.4 m/s while gas superficial velocity ranged from 0.3 to 10.0 m/s. The measured parameters include liquid holdup, pressure gradient, flow pattern, and slug flow features. The flow patterns observed were stratified, stratified-wavy, plug, slug, and annular flows. Plug and slug flow patterns showed good agreement with established flow pattern maps. Furthermore, the slug translational velocity was observed to increase with increasing mixture velocity, as reported by previous authors, hence establishing the reliability of the instrumentation employed. The slug body length was also measured using the gamma densitometer and was found to be within the range 24–36D with a mean length of 30.6D.

Keywords:Gamma Densitometry, Two-phase flow, Slug Flow, Pressure gradient, Liquid holdup
Subjects:H Engineering > H850 Petroleum Engineering
H Engineering > H141 Fluid Mechanics
H Engineering > H800 Chemical, Process and Energy Engineering
H Engineering > H300 Mechanical Engineering
Divisions:College of Science > School of Engineering
ID Code:48023
Deposited On:15 Aug 2022 14:27

Repository Staff Only: item control page