Tew, Garry A., Klonizakis, Markos, Crank, Helen , Briers, J. David and Hodges, Gary J. (2011) Comparison of laser speckle contrast imaging with laser Doppler for assessing microvascular function. Microvascular Research, 82 (3). pp. 326-332. ISSN 0026-2862
Full content URL: http://dx.doi.org/10.1016/j.mvr.2011.07.007
Documents |
|
| ||||||||||||
|
| ||||||||||||
|
| ||||||||||||
|
| ||||||||||||
|
| ||||||||||||
|
| ||||||||||||
|
| ||||||||||||
|
| ||||||||||||
|
| ||||||||||||
|
| ||||||||||||
|
|
![]() |
Microsoft Word
Fig_1A.docx - Image Restricted to Repository staff only 21kB | |
![]() |
Microsoft Word
Fig_1B.docx - Image Restricted to Repository staff only 21kB | |
![]() |
Microsoft Word
Fig_1C.docx Restricted to Repository staff only 19kB | |
![]() |
Microsoft Word
Fig_2.docx Restricted to Repository staff only 24kB | |
![]() |
Microsoft Word
Fig_3.docx Restricted to Repository staff only 25kB | |
![]() |
Microsoft Word
Fig_4.docx Restricted to Repository staff only 68kB | |
![]() |
Microsoft Word
Manuscript_v2.doc - Whole Document Restricted to Repository staff only 217kB | |
![]() |
Microsoft Word
Table_1.docx Restricted to Repository staff only 17kB | |
![]() |
Microsoft Word
Table_2.docx Restricted to Repository staff only 17kB | |
![]() |
Microsoft Word
Table_3.docx Restricted to Repository staff only 17kB | |
![]() |
Microsoft Word
Table_4.docx Restricted to Repository staff only 16kB | |
![]()
|
PDF
Manuscript_v2.pdf - Whole Document 124kB | |
![]()
|
PDF
Fig_1A.pdf - Image 74kB | |
![]()
|
PDF
Fig_1B.pdf - Image 74kB | |
![]()
|
PDF
Fig_1C.pdf - Image 73kB | |
![]()
|
PDF
Fig_2.pdf - Image 75kB | |
![]()
|
PDF
Fig_3.pdf - Image 97kB | |
![]()
|
PDF
Fig_4.pdf - Image 63kB | |
![]()
|
PDF
Table_1.pdf - Image 67kB | |
![]()
|
PDF
Table_2.pdf - Image 67kB | |
![]()
|
PDF
Table_3.pdf - Image 67kB | |
![]()
|
PDF
Table_4.pdf - Image 61kB |
Item Type: | Article |
---|---|
Item Status: | Live Archive |
Abstract
Objective: To compare the inter-day reproducibility of post-occlusive reactive hyperaemia (PORH) and sympathetic vasomotor reflexes assessed by single-point laser Doppler flowmetry (SP-LDF), integrating-probe LDF (IP-LDF) and laser speckle contrast imaging (LSCI), and the spatial variability of PORH assessed by IP-LDF and LSCI. We also evaluated the relationship between IP-LDF and LSCI perfusion values across a broad range of skin blood flows.
Methods: Eighteen healthy adults (50% male, age 27 ± 4 years) participated in this study. Using SP-LDF, IP-LDF and LSCI, an index of skin blood flow was measured on the forearm during PORH (1-, 5- and 10-min occlusions) and on the finger pad during inspiratory gasp and cold pressor tests. These tests were repeated 3-7 days later. Data were converted to cutaneous vascular conductance (CVC; laser Doppler flow/mean arterial pressure) and expressed as absolute and relative changes from pre-stimulus CVC (ΔCVCABS and ΔCVCREL, respectively), as well as normalised to peak CVC for the PORH tests. Reproducibility was expressed as within-subjects coefficients of variation (CV, in %) and intraclass correlation coefficients.
Results: The reproducibility of PORH on the forearm was poorer when assessed with SP-LDF and IP-LDF compared to LSCI (e.g., CV for 5-min PORH ΔCVCABS = 35, 27 and 19%, respectively), with no superior method of data expression. In contrast, the reproducibility of the inspiratory gasp and cold pressor test responses on the finger pad were better with SP-LDF and IP-LDF compared to LSCI (e.g., CV for inspiratory gasp ΔCVCREL = 13, 7 and 19%, respectively). The spatial variability of PORH responses was poorer with IP-LDF compared to LSCI (e.g., CV ranging 11-35% versus 3-16%, respectively). The association between simultaneous LSCI and IP-LDF perfusion values was non-linear.
Conclusion: The reproducibility of cutaneous PORH was better when assessed with LSCI compared to SP-LDF and IP-LDF; probably due to measuring larger skin areas (lower inter-site variability). However, when measuring sympathetic vasomotor reflexes on the finger pad, reproducibility was better with SP-LDF and IP-LDF, perhaps due to the high sensitivity of LSCI to changes in skin blood flow at low levels.
Additional Information: | Objective: To compare the inter-day reproducibility of post-occlusive reactive hyperaemia (PORH) and sympathetic vasomotor reflexes assessed by single-point laser Doppler flowmetry (SP-LDF), integrating-probe LDF (IP-LDF) and laser speckle contrast imaging (LSCI), and the spatial variability of PORH assessed by IP-LDF and LSCI. We also evaluated the relationship between IP-LDF and LSCI perfusion values across a broad range of skin blood flows. Methods: Eighteen healthy adults (50% male, age 27 ± 4 years) participated in this study. Using SP-LDF, IP-LDF and LSCI, an index of skin blood flow was measured on the forearm during PORH (1-, 5- and 10-min occlusions) and on the finger pad during inspiratory gasp and cold pressor tests. These tests were repeated 3-7 days later. Data were converted to cutaneous vascular conductance (CVC; laser Doppler flow/mean arterial pressure) and expressed as absolute and relative changes from pre-stimulus CVC (ΔCVCABS and ΔCVCREL, respectively), as well as normalised to peak CVC for the PORH tests. Reproducibility was expressed as within-subjects coefficients of variation (CV, in %) and intraclass correlation coefficients. Results: The reproducibility of PORH on the forearm was poorer when assessed with SP-LDF and IP-LDF compared to LSCI (e.g., CV for 5-min PORH ΔCVCABS = 35, 27 and 19%, respectively), with no superior method of data expression. In contrast, the reproducibility of the inspiratory gasp and cold pressor test responses on the finger pad were better with SP-LDF and IP-LDF compared to LSCI (e.g., CV for inspiratory gasp ΔCVCREL = 13, 7 and 19%, respectively). The spatial variability of PORH responses was poorer with IP-LDF compared to LSCI (e.g., CV ranging 11-35% versus 3-16%, respectively). The association between simultaneous LSCI and IP-LDF perfusion values was non-linear. Conclusion: The reproducibility of cutaneous PORH was better when assessed with LSCI compared to SP-LDF and IP-LDF; probably due to measuring larger skin areas (lower inter-site variability). However, when measuring sympathetic vasomotor reflexes on the finger pad, reproducibility was better with SP-LDF and IP-LDF, perhaps due to the high sensitivity of LSCI to changes in skin blood flow at low levels. |
---|---|
Keywords: | LASCA, laser Doppler flowmetry, reliability, blood flow, reactivity, skin |
Subjects: | A Medicine and Dentistry > A100 Pre-clinical Medicine |
Divisions: | College of Social Science > School of Health & Social Care |
ID Code: | 4582 |
Deposited On: | 25 Jul 2011 21:50 |
Repository Staff Only: item control page