O'Shea, Simon and Grafton, Kate (2013) The intra and inter-rater reliability of a modified weight-bearing lunge measure of ankle dorsiflexion. Manual Therapy, 18 (3). pp. 264-268. ISSN 1356-689X
Full content URL: https://doi.org/10.1016/j.math.2012.08.007
Documents |
|
![]() |
PDF
Simon OShea & KG Manual Therapy Article.pdf - Whole Document Restricted to Repository staff only 561kB |
Item Type: | Article |
---|---|
Item Status: | Live Archive |
Abstract
This study assessed the intra and inter-rater reliability of a modified weight-bearing lunge measure of ankle dorsiflexion range of movement. Thirteen healthy subjects were recruited. Each subject performed 3 repetitions of the lunging method with one rater and 3 more repetitions with a second rater within 30 min. The process was repeated within 3 h. Intra-rater reliability results indicated excellent correlation of measurements (intraclass correlation coefficients (ICCs) of 0.98-0.99). Standard error of measurement (SEM), 95% limits of agreement (LOA) and coefficient of repeatability (CR) calculations indicated suitably low ranges of measurement variance (SEM = 0.4 cm, LOA = ± 1.28 to ± 1.47 cm and CR = 1.21-1.35 cm). Inter-rater reliability was also deemed excellent (ICC = 0.99, SEM = 0.3 cm, LOA = ± 0.83 to ± 1.47 cm, CR = 1.44 cm). The modified lunge technique therefore demonstrates excellent intra and inter-rater reliability.
Keywords: | dorsiflexion, Reliability, lunge ankle |
---|---|
Subjects: | B Subjects allied to Medicine > B160 Physiotherapy |
Divisions: | College of Social Science > School of Health & Social Care |
ID Code: | 44777 |
Deposited On: | 05 May 2021 08:24 |
Repository Staff Only: item control page