Gonzalez-Rodriguez, Jose, Perez Juan, Pedro and Luque de Castro, Maria Dolores (2002) Flow injection determination of total catechins and procyanidins in white and red wines. Innovative Food Science and Emerging Technologies, 3 (3). pp. 289-293. ISSN 1466-8564
Full content URL: http://dx.doi.org/10.1016/s1466-8564(02)00029-2
Documents |
|
![]()
|
PDF
Food_and_emerging_technologies_2002.pdf Available under License Creative Commons Attribution Non-commercial. 139kB |
Item Type: | Article |
---|---|
Item Status: | Live Archive |
Abstract
An easily automatable flow-injection (FI) method for the determination of total catechins is reported. The method is based on the reaction of vanillin in acid medium to yield a coloured product with maximum absorption at 500 nm. After optimisation by the univariate and multivariate approaches as required, the linear range was established (between 10 and 90 mgL-1 and 10 and 250 mgL-1 for white and red wines, respectively). Then, the assessment of the proposed versus the reference method was studied in terms of repeatability (2.57 mgL-1), reproducibility (3.56 mgL-1) (no significant differences were found), detection and quantification limits (not far from those of the reference method and always sufficient for the determination of catechins in any type of wine), traceability (excellent correlation under all conditions) and sample throughput (23 samples h-1 for the proposed method versus 3 samples h-1 for the reference method).
Additional Information: | An easily automatable flow-injection (FI) method for the determination of total catechins is reported. The method is based on the reaction of vanillin in acid medium to yield a coloured product with maximum absorption at 500 nm. After optimisation by the univariate and multivariate approaches as required, the linear range was established (between 10 and 90 mgL-1 and 10 and 250 mgL-1 for white and red wines, respectively). Then, the assessment of the proposed versus the reference method was studied in terms of repeatability (2.57 mgL-1), reproducibility (3.56 mgL-1) (no significant differences were found), detection and quantification limits (not far from those of the reference method and always sufficient for the determination of catechins in any type of wine), traceability (excellent correlation under all conditions) and sample throughput (23 samples h-1 for the proposed method versus 3 samples h-1 for the reference method). |
---|---|
Keywords: | procyanidins, catechins, flow injection, analytical chemistry, method validation, food chemistry, method optimisation, automation, spectrophotometry, wine |
Subjects: | F Physical Sciences > F110 Applied Chemistry F Physical Sciences > F190 Chemistry not elsewhere classified F Physical Sciences > F100 Chemistry F Physical Sciences > F180 Analytical Chemistry |
Divisions: | College of Science > School of Life Sciences |
ID Code: | 2118 |
Deposited On: | 08 Jan 2010 09:50 |
Repository Staff Only: item control page