Owen, I., Fyrippi, I. and Escudier, M. P. (2003) Flowmetering of shear-thinning non-Newtonian liquids. In: 4th ASME/JSME Joint Fluids Engineering Conference, 6 - 10 July 2003, Honolulu, Hawaii.
Full content URL: http://www.scopus.com/inward/record.url?eid=2-s2.0...
Full text not available from this repository.
Item Type: | Conference or Workshop contribution (Paper) |
---|---|
Item Status: | Live Archive |
Abstract
This paper describes the results of an investigation into the performance of Coriolis, Electromagnetic, and clamp-on single-beam Ultrasonic flowmeters operating with non-Newtonian liquids. The flowmeters have been tested on Newtonian liquids (water and a glycerine/water solution) and non-Newtonian liquids (various polymer solutions and a synthetic clay) with flow rates that span the laminar and turbulent regions. It has been shown that the Coriolis flowmeter operates within the manufacturer's specification with non-Newtonian liquids. The Electromagnetic flowmeter showed a slight deviation during transition, typically 1. The Ultrasonic flowmeter showed very significant deviations during transition, typically 15. It has been clearly demonstrated that flowmeters which are sensitive to flow velocity profile are particularly unsuitable for use with non-Newtonian liquids. Not only do non-Newtonian liquids have different flow velocity profiles to Newtonian liquids, they also have different criteria for laminar/turbulent transition.
Additional Information: | Conference Code:62091 |
---|---|
Keywords: | Flow measurement, Glycerol, Laminar flow, Magnetoelectric effects, Reynolds number, Turbulent flow, Ultrasonic flowmeters, Velocity measurement, Viscosity, Water, Yield stress, Shear-thinning, Turbulent regions, Non Newtonian liquids |
Subjects: | H Engineering > H100 General Engineering H Engineering > H141 Fluid Mechanics |
Divisions: | College of Science > School of Engineering |