Analysis of KrF excimer laser beam modification resulting from ablation under closed thick film flowing filtered water

Dowding, Colin and Lawrence, Jonathan (2011) Analysis of KrF excimer laser beam modification resulting from ablation under closed thick film flowing filtered water. Optics and Laser Technology, 43 (6). pp. 1026-1035. ISSN 0030-3992

[img]
Preview
PDF
Analysis_of_beam_modification_caused_by_the_closed_thick_film_immersed_KrF_excimer_laser_ablation_technique.pdf - Whole Document

Download (689Kb)

Abstract

The application of closed thick film liquid to immerse the ablation etching mechanism of an excimer laser poses interesting possibilities concerning debris control, modification of machined feature topography and modification of ablation rate. Further more, these parameters have been shown to be dependant on flow velocity; hence offering further user control of machining characteristics. However the impact of this technique requires investigation. This contribution offers comparison of the calculated ablation pressure and the effect on feature surface characteristics given for laser ablation of bisphenol A polycarbonate using KrF excimer laser radiation in ambient air against laser ablation of the same substrate under closed thick film flowing filtered water immersion. Also, the impact of such immersion equipment on the optical performance of the micromachining centre used is quantified and reviewed. The pressure is calculated to have risen some 53% when using the liquid immersed ablation technique. This increase in pressure is proposed to have promoted the frequency of surface Plasmons and asperities with a surface area less than 16 µm2. The focal length of the optical system was accurately predicted to be increased by 2.958 mm when using the equipment composed of a 5 mm thick ultraviolet grade fused silica window covering a 1.5 mm thick film of filtered water flowing at 1.85 m/s. This equipment was predicted to have increased the optical depth of focus via reduction in the angle of convergence of the two defining image rays, yet the perceived focus, measured by mean feature wall angle as a discrete indication, was found to be 25% smaller when using the closed thick film flowing filtered water immersion technique than when laser ablating in ambient air. A compressed plume interaction is proposed as a contributing factor in this change.

Item Type: Article
Additional Information: The application of closed thick film liquid to immerse the ablation etching mechanism of an excimer laser poses interesting possibilities concerning debris control, modification of machined feature topography and modification of ablation rate. Further more, these parameters have been shown to be dependant on flow velocity; hence offering further user control of machining characteristics. However the impact of this technique requires investigation. This contribution offers comparison of the calculated ablation pressure and the effect on feature surface characteristics given for laser ablation of bisphenol A polycarbonate using KrF excimer laser radiation in ambient air against laser ablation of the same substrate under closed thick film flowing filtered water immersion. Also, the impact of such immersion equipment on the optical performance of the micromachining centre used is quantified and reviewed. The pressure is calculated to have risen some 53% when using the liquid immersed ablation technique. This increase in pressure is proposed to have promoted the frequency of surface Plasmons and asperities with a surface area less than 16 µm2. The focal length of the optical system was accurately predicted to be increased by 2.958 mm when using the equipment composed of a 5 mm thick ultraviolet grade fused silica window covering a 1.5 mm thick film of filtered water flowing at 1.85 m/s. This equipment was predicted to have increased the optical depth of focus via reduction in the angle of convergence of the two defining image rays, yet the perceived focus, measured by mean feature wall angle as a discrete indication, was found to be 25% smaller when using the closed thick film flowing filtered water immersion technique than when laser ablating in ambient air. A compressed plume interaction is proposed as a contributing factor in this change.
Keywords: Liquid Immersion, Excimer Feature, Quality, Ablation, Topography, ref15, refdoi
Subjects: H Engineering > H680 Optoelectronic Engineering
H Engineering > H700 Production and Manufacturing Engineering
F Physical Sciences > F361 Laser Physics
H Engineering > H300 Mechanical Engineering
Divisions: College of Sciences > Faculty of Science > Lincoln School of Engineering
Depositing User: Colin Dowding
Date Deposited: 17 Feb 2011 16:53
Last Modified: 12 Apr 2013 10:21
URI: http://eprints.lincoln.ac.uk/id/eprint/4035

Actions (login required)

View Item View Item